@ -8,7 +8,8 @@ services:
|
||||
# - MD1200BAUD=
|
||||
- SERIALADAPTER=/dev/ttyUSB0
|
||||
- TEMP_FACTOR=17
|
||||
# - EPPYSLEEPY=
|
||||
- EPPYSLEEPY=0.25
|
||||
- MDSERIALTIMEOUT=0.75
|
||||
# - LOW_FAN_TRSHD=
|
||||
# - HIGH_FAN_TRSHD=
|
||||
devices:
|
||||
|
@ -7,9 +7,9 @@ MD1200BAUD = int(os.getenv("MD1200BAUD", 38400))
|
||||
# used if you want to run it on multiple JBODs
|
||||
SERIALADAPTER = os.getenv("SERIALADAPTER", "/dev/ttyUSB0")
|
||||
# Factor that defines how aggressive the temperature curve is
|
||||
TEMP_FACTOR = int(os.getenv("TEMP_FACTOR", 19))
|
||||
TEMP_FACTOR = int(os.getenv("TEMP_FACTOR", 16))
|
||||
# time between sending command to get temp and storing it. It's there to allow JBOD to answer
|
||||
EPPYSLEEPY = float(os.getenv("EPPYSLEEPY", 0.25))
|
||||
EPPYSLEEPY = float(os.getenv("EPPYSLEEPY", 1))
|
||||
|
||||
LOW_FAN_TRSHD = int(os.getenv("LOW_FAN_TRSHD", 21))
|
||||
HIGH_FAN_TRSHD = int(os.getenv("HIGH_FAN_TRSHD", 40))
|
||||
@ -19,7 +19,11 @@ SETFANCMND = os.getenv("SETFANCMND", "set_speed")
|
||||
|
||||
DEFOUTPRCNTG = int(os.getenv("DEFOUTPRCNTG", 24))
|
||||
|
||||
MDSERIALTIMEOUT = float(os.getenv("MDSERIALTIMEOUT", 1))
|
||||
|
||||
TEMPREADINTERVAL = int(os.getenv("TEMPREADINTERVAL", 15))
|
||||
|
||||
GETTEMPTIMESLEEP = int(os.getenv("GETTEMPTIMESLEEP", 1))
|
||||
|
||||
# init
|
||||
MDserial = serial.Serial(
|
||||
@ -28,18 +32,25 @@ MDserial = serial.Serial(
|
||||
parity=serial.PARITY_NONE,\
|
||||
stopbits=serial.STOPBITS_ONE,\
|
||||
bytesize=serial.EIGHTBITS,\
|
||||
timeout=1)
|
||||
timeout=MDSERIALTIMEOUT)
|
||||
|
||||
lastTempReading = time.time()
|
||||
MDtempDict = {}
|
||||
|
||||
|
||||
def getTemp():
|
||||
|
||||
MDserial.write(f"{GETTMPCMND}\n\r".encode())
|
||||
time.sleep(GETTEMPTIMESLEEP)
|
||||
MDreturning = MDserial.read_until(" >").decode(errors="ignore")
|
||||
|
||||
def getTemp(inpMDreturning):
|
||||
MDict = {}
|
||||
|
||||
# Sanitise output
|
||||
MDsanit = inpMDreturning.splitlines()
|
||||
MDsanit = MDreturning.splitlines()
|
||||
|
||||
#if there is smth do smth
|
||||
if inpMDreturning:
|
||||
if MDreturning:
|
||||
|
||||
for line in MDsanit:
|
||||
|
||||
@ -61,10 +72,27 @@ def getTemp(inpMDreturning):
|
||||
MDict["exp0"] = int(line[12:14])
|
||||
case "EXP1":
|
||||
MDict["exp1"] = int(line[12:14])
|
||||
case "AVG":
|
||||
MDict["avg"] = int(line[12:14])
|
||||
# case "AVG":
|
||||
# MDict["avg"] = int(line[12:14])
|
||||
# MDict["avg"] = int(line.strip().split("=")[1].strip().replace("c", ""))
|
||||
# try:
|
||||
# # Extract number from e.g. ' AVG = 40c'
|
||||
# temp = int(line.strip().split("=")[1].strip().replace("c", ""))
|
||||
# MDict["avg"] = temp
|
||||
# except Exception as e:
|
||||
# # print(f"[WARN] Failed to parse AVG line: {line} ({e})", flush=True)
|
||||
# pass
|
||||
case _:
|
||||
continue
|
||||
# try to catch the AVG line like: " AVG = 40c"
|
||||
stripped = line.strip()
|
||||
if stripped.startswith("AVG"):
|
||||
try:
|
||||
temp = int(stripped.split("=")[1].strip().replace("c", ""))
|
||||
MDict["avg"] = temp
|
||||
except Exception as e:
|
||||
print(f"Could not parse AVG line: {line} ({e})", flush=True)
|
||||
continue
|
||||
# continue
|
||||
return MDict
|
||||
|
||||
|
||||
@ -75,15 +103,15 @@ def setSpeed(inSpeeDict: dict):
|
||||
outfanprcntg = 0
|
||||
|
||||
# get backplanbe average
|
||||
if inSpeeDict["bp1"] and inSpeeDict["bp2"]:
|
||||
if "bp1" in inSpeeDict and "bp2" in inSpeeDict:
|
||||
bpavrg = (inSpeeDict["bp1"] + inSpeeDict["bp2"]) /2
|
||||
outfanprcntg = int((bpavrg / (HIGH_FAN_TRSHD - LOW_FAN_TRSHD)) * TEMP_FACTOR)
|
||||
os.system(f"echo setting {outfanprcntg}%")
|
||||
# os.system(f"echo setting {outfanprcntg}%")
|
||||
|
||||
# Set fan speed
|
||||
if outfanprcntg >= 20:
|
||||
MDserial.write((f"{SETFANCMND} {str(outfanprcntg)} \n\r").encode())
|
||||
print(f"setting {outfanprcntg}%")
|
||||
print(f"setting {outfanprcntg}%", flush=True)
|
||||
return 0
|
||||
else:
|
||||
# Set default value
|
||||
@ -105,35 +133,57 @@ def setSpeed(inSpeeDict: dict):
|
||||
# # MDserial.open()
|
||||
# print("Port allready opened.\nTry closing it first")
|
||||
|
||||
while True:
|
||||
# https://stackoverflow.com/questions/52578122/not-able-to-send-the-enter-command-on-pyserial
|
||||
# Init
|
||||
MDtempDict = getTemp()
|
||||
lastTempReading = time.time()
|
||||
try:
|
||||
|
||||
# get temperature data, wait for MD1200 to answer and store
|
||||
MDserial.write(f"{GETTMPCMND}\n\r".encode())
|
||||
time.sleep(EPPYSLEEPY)
|
||||
MDreturning = MDserial.read_until(" >").decode()
|
||||
while True:
|
||||
# https://stackoverflow.com/questions/52578122/not-able-to-send-the-enter-command-on-pyserial
|
||||
|
||||
MDtempDict = getTemp(MDreturning)
|
||||
setSpeedrcode = setSpeed(MDtempDict)
|
||||
# get temperature data, wait for MD1200 to answer and store
|
||||
|
||||
# good
|
||||
if setSpeedrcode == 0:
|
||||
continue
|
||||
# print("Were mint")
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# not good
|
||||
elif setSpeedrcode == 1:
|
||||
print("Ambigous temperature readings.\nFalling back to safe values.")
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# very not good
|
||||
elif setSpeedrcode == -1:
|
||||
print("o nyo")
|
||||
exit()
|
||||
# very very very not good
|
||||
else:
|
||||
print("idk")
|
||||
exit()
|
||||
currentTime = time.time()
|
||||
|
||||
if currentTime - lastTempReading >= TEMPREADINTERVAL:
|
||||
MDtempDict = getTemp()
|
||||
lastTempReading = currentTime
|
||||
|
||||
if MDtempDict:
|
||||
setSpeedrcode = setSpeed(MDtempDict)
|
||||
|
||||
# good
|
||||
if setSpeedrcode == 0:
|
||||
pass
|
||||
# print("Were mint", flush=True)
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# not good
|
||||
elif setSpeedrcode == 1:
|
||||
print("Ambigous temperature readings.\nFalling back to safe values.", flush=True)
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# very not good
|
||||
elif setSpeedrcode == -1:
|
||||
print("o nyo", flush=True)
|
||||
exit()
|
||||
# very very very not good
|
||||
else:
|
||||
print("idk", flush=True)
|
||||
exit()
|
||||
else:
|
||||
print(f"temperature not yet pulled.\nFalling back do default fan speed", flush=True)
|
||||
# os.system(f"echo temperature not yet pulled.\nFalling back do default fan speed")
|
||||
MDserial.write((f"{SETFANCMND} {str(DEFOUTPRCNTG)} \n\r").encode())
|
||||
|
||||
time.sleep(EPPYSLEEPY)
|
||||
|
||||
except KeyboardInterrupt:
|
||||
print("\n[INFO] KeyboardInterrupt detected. Exiting gracefully...")
|
||||
MDserial.close()
|
||||
exit()
|
||||
|
||||
finally:
|
||||
print("closing port")
|
||||
MDserial.close()
|
||||
|
||||
print("closing port")
|
||||
MDserial.close()
|
||||
|
28
PC_CONTROL_CODE/dockerInflux/Dockerfile
Normal file
28
PC_CONTROL_CODE/dockerInflux/Dockerfile
Normal file
@ -0,0 +1,28 @@
|
||||
FROM alpine:latest
|
||||
|
||||
# https://docs.docker.com/reference/dockerfile/#environment-replacement
|
||||
# ENV MD1200BAUD=38400
|
||||
# ENV SERIALADAPTER=/dev/ttyUSB0
|
||||
# ENV EPPYSLEEPY=300
|
||||
|
||||
# VOLUME [""]
|
||||
|
||||
RUN apk update && \
|
||||
apk add python3 py3-pip
|
||||
|
||||
RUN mkdir /etc/MD1200FAN/
|
||||
WORKDIR /etc/MD1200FAN/
|
||||
|
||||
COPY ./mainDocker.py /etc/MD1200FAN/
|
||||
# COPY ./requirements.txt /etc/MD1200FAN/
|
||||
|
||||
RUN python3 -m venv venv && \
|
||||
venv/bin/python3 -m pip install --upgrade pip && \
|
||||
venv/bin/pip3 install PySerial influxdb_client
|
||||
# venv/bin/pip3 install -r requirements.txt
|
||||
|
||||
# VOLUME ["/etc/MD1200FAN/"]
|
||||
|
||||
CMD ["venv/bin/python3", "mainDocker.py"]
|
||||
|
||||
# CMD ["/etc/MD1200FAN/venv/bin/python3", "/etc/MD1200FAN/mainDocker.py"]
|
19
PC_CONTROL_CODE/dockerInflux/docker-compose.yml
Normal file
19
PC_CONTROL_CODE/dockerInflux/docker-compose.yml
Normal file
@ -0,0 +1,19 @@
|
||||
---
|
||||
|
||||
services:
|
||||
mdfanchanger:
|
||||
container_name: MD_Fan_Changer
|
||||
image: yuruc3/md1200_fan_controll:v1.2.1
|
||||
environment:
|
||||
# - MD1200BAUD=
|
||||
- SERIALADAPTER=/dev/ttyUSB0
|
||||
- TEMP_FACTOR=17
|
||||
- EPPYSLEEPY=0.5
|
||||
- MDSERIALTIMEOUT=0.5
|
||||
# - LOW_FAN_TRSHD=
|
||||
# - HIGH_FAN_TRSHD=
|
||||
env_file: "md1200.env"
|
||||
devices:
|
||||
- /dev/ttyUSB0:/dev/ttyUSB0
|
||||
restart: unless-stopped
|
||||
privileged: false
|
54
PC_CONTROL_CODE/dockerInflux/influxSend.py
Normal file
54
PC_CONTROL_CODE/dockerInflux/influxSend.py
Normal file
@ -0,0 +1,54 @@
|
||||
import time, os, influxdb_client
|
||||
from influxdb_client import InfluxDBClient, Point, WritePrecision
|
||||
from influxdb_client.client.write_api import SYNCHRONOUS, ASYNCHRONOUS, WriteOptions
|
||||
from datetime import timedelta
|
||||
from concurrent.futures import ThreadPoolExecutor
|
||||
|
||||
|
||||
# INFLUXDB config
|
||||
# token = "apg1gysUeCcxdcRTMmosJTenbEppmUNi9rXlANDB2oNadBdWAu2GVTDc_q_dyo0iyYsckKaOvPRm6ba2NK0y_A=="
|
||||
token = os.getenv("INFLUX_TOKEN")
|
||||
# bucket = "JBOD"
|
||||
bucket = os.getenv("INFLUX_BUCKET")
|
||||
# org = "staging"
|
||||
org = os.getenv("INFLUX_ORG")
|
||||
# url = "http://localhost:8086"
|
||||
url = os.getenv("INFLUX_URL")
|
||||
# measurement = "MD1200"
|
||||
measurement = os.getenv("INFLUX_MEASUREMENT")
|
||||
# MACHINE_TAG = "CHONGUS1200"
|
||||
MACHINE_TAG = os.getenv("INFLUX_MACHINE_TAG")
|
||||
# LOCATION = "HQ"
|
||||
LOCATION = os.getenv("INFLUX_LOCATION")
|
||||
# INFLX_SEPARATE_POINTS = 0.1
|
||||
INFLUX_SEPARATE_POINTS = int(os.getenv("INFLUX_SEPARATE_POINTS"))
|
||||
|
||||
# Initialize InfluxDB client and influxdb API
|
||||
inflxdb_client = influxdb_client.InfluxDBClient(url=url, token=token, org=org)
|
||||
#write_api = inflxdb_client.write_api(write_options=SYNCHRONOUS)
|
||||
write_api = inflxdb_client.write_api(write_options=WriteOptions(batch_size=500, flush_interval=1000))
|
||||
|
||||
# Threaded flow processor
|
||||
def process_temps(inEntry):
|
||||
global MDict
|
||||
|
||||
# ---LeData---
|
||||
# {'bp1': 35, 'bp2': 29, 'sim0': 35, 'sim1': 34, 'exp0': 56, 'exp1': 54}
|
||||
# ---LeData---
|
||||
|
||||
# Prep InfluxDB data
|
||||
inflxdb_Data_To_Send = (
|
||||
influxdb_client.Point(f"{measurement}-script")
|
||||
.tag("MACHINE", MACHINE_TAG)
|
||||
.tag("LOCATION", LOCATION)
|
||||
.field("Backplane1", inEntry["bp1"])
|
||||
.field("Backplane2", inEntry["bp2"])
|
||||
.field("SASIntModule0", inEntry["sim0"])
|
||||
.field("SASIntModule1", inEntry["sim1"])
|
||||
.field("Expander0", inEntry["exp0"])
|
||||
.field("Expander1", inEntry["exp1"])
|
||||
.field("Average", inEntry["avg"])
|
||||
)
|
||||
|
||||
print("----------------")
|
||||
return ()
|
273
PC_CONTROL_CODE/dockerInflux/mainDocker.py
Normal file
273
PC_CONTROL_CODE/dockerInflux/mainDocker.py
Normal file
@ -0,0 +1,273 @@
|
||||
import time, os, influxdb_client, serial, threading
|
||||
from influxdb_client import InfluxDBClient, Point, WritePrecision
|
||||
from influxdb_client.client.write_api import SYNCHRONOUS, ASYNCHRONOUS, WriteOptions
|
||||
from concurrent.futures import ThreadPoolExecutor
|
||||
|
||||
# setting consts that can be customized
|
||||
|
||||
# baud rate. Prob not needed as 38400 is standard
|
||||
MD1200BAUD = int(os.getenv("MD1200BAUD", 38400))
|
||||
# used if you want to run it on multiple JBODs
|
||||
SERIALADAPTER = os.getenv("SERIALADAPTER", "/dev/ttyUSB0")
|
||||
# Factor that defines how aggressive the temperature curve is
|
||||
TEMP_FACTOR = int(os.getenv("TEMP_FACTOR", 16))
|
||||
# time between sending command to get temp and storing it. It's there to allow JBOD to answer
|
||||
EPPYSLEEPY = float(os.getenv("EPPYSLEEPY", 1))
|
||||
|
||||
LOW_FAN_TRSHD = int(os.getenv("LOW_FAN_TRSHD", 21))
|
||||
HIGH_FAN_TRSHD = int(os.getenv("HIGH_FAN_TRSHD", 40))
|
||||
|
||||
GETTMPCMND = os.getenv("GETTMPCMND", "_temp_rd")
|
||||
SETFANCMND = os.getenv("SETFANCMND", "set_speed")
|
||||
|
||||
DEFOUTPRCNTG = int(os.getenv("DEFOUTPRCNTG", 24))
|
||||
|
||||
MDSERIALTIMEOUT = float(os.getenv("MDSERIALTIMEOUT", 1))
|
||||
|
||||
TEMPREADINTERVAL = float(os.getenv("TEMPREADINTERVAL", 15))
|
||||
|
||||
# INFLUXDB config
|
||||
# token = "apg1gysUeCcxdcRTMmosJTenbEppmUNi9rXlANDB2oNadBdWAu2GVTDc_q_dyo0iyYsckKaOvPRm6ba2NK0y_A=="
|
||||
token = os.getenv("INFLUX_TOKEN")
|
||||
# bucket = "JBOD"
|
||||
bucket = os.getenv("INFLUX_BUCKET")
|
||||
# org = "staging"
|
||||
org = os.getenv("INFLUX_ORG")
|
||||
# url = "http://localhost:8086"
|
||||
url = os.getenv("INFLUX_URL")
|
||||
# measurement = "MD1200"
|
||||
measurement = os.getenv("INFLUX_MEASUREMENT")
|
||||
# MACHINE_TAG = "CHONGUS1200"
|
||||
MACHINE_TAG = os.getenv("INFLUX_MACHINE_TAG")
|
||||
# LOCATION = "HQ"
|
||||
LOCATION = os.getenv("INFLUX_LOCATION")
|
||||
# INFLX_SEPARATE_POINTS = 0.1
|
||||
# INFLUX_SEPARATE_POINTS = float(os.getenv("INFLUX_SEPARATE_POINTS"), 0.1)
|
||||
|
||||
# init
|
||||
MDserial = serial.Serial(
|
||||
port=SERIALADAPTER,\
|
||||
baudrate=MD1200BAUD,\
|
||||
parity=serial.PARITY_NONE,\
|
||||
stopbits=serial.STOPBITS_ONE,\
|
||||
bytesize=serial.EIGHTBITS,\
|
||||
timeout=MDSERIALTIMEOUT)
|
||||
|
||||
lastTempReading = time.time()
|
||||
MDtempDict = {}
|
||||
MDict = {}
|
||||
fluxSending = False
|
||||
currentTime = 0
|
||||
lastTempReading = 0
|
||||
# Initialize InfluxDB client and influxdb API
|
||||
# ---------------------UNCOMMENT-----------------------
|
||||
# inflxdb_client = influxdb_client.InfluxDBClient(url=url, token=token, org=org)
|
||||
# write_api = inflxdb_client.write_api(write_options=SYNCHRONOUS)
|
||||
# ---------------------UNCOMMENT-----------------------
|
||||
|
||||
|
||||
def getTemp():
|
||||
global MDict, fluxSending
|
||||
|
||||
MDserial.write(f"{GETTMPCMND}\n\r".encode())
|
||||
time.sleep(1)
|
||||
MDreturning = MDserial.read_until(" >").decode()
|
||||
|
||||
# MDict = {}
|
||||
|
||||
# Sanitise output
|
||||
MDsanit = MDreturning.splitlines()
|
||||
|
||||
#if there is smth do smth
|
||||
if MDreturning:
|
||||
|
||||
for line in MDsanit:
|
||||
|
||||
if ">" in line or "b'" in line:
|
||||
continue
|
||||
|
||||
matchstm = line[2:6]
|
||||
|
||||
match matchstm:
|
||||
case "BP_1":
|
||||
MDict["bp1"] = int(line[12:14])
|
||||
case "BP_2":
|
||||
MDict["bp2"] = int(line[12:14])
|
||||
case "SIM0":
|
||||
MDict["sim0"] = int(line[12:14])
|
||||
case "SIM1":
|
||||
MDict["sim1"] = int(line[12:14])
|
||||
case "EXP0":
|
||||
MDict["exp0"] = int(line[12:14])
|
||||
case "EXP1":
|
||||
MDict["exp1"] = int(line[12:14])
|
||||
# case "AVG":
|
||||
# MDict["avg"] = int(line[12:14])
|
||||
# MDict["avg"] = int(line.strip().split("=")[1].strip().replace("c", ""))
|
||||
# try:
|
||||
# # Extract number from e.g. ' AVG = 40c'
|
||||
# temp = int(line.strip().split("=")[1].strip().replace("c", ""))
|
||||
# MDict["avg"] = temp
|
||||
# except Exception as e:
|
||||
# # print(f"[WARN] Failed to parse AVG line: {line} ({e})", flush=True)
|
||||
# pass
|
||||
case _:
|
||||
# try to catch the AVG line like: " AVG = 40c"
|
||||
stripped = line.strip()
|
||||
if stripped.startswith("AVG"):
|
||||
try:
|
||||
temp = int(stripped.split("=")[1].strip().replace("c", ""))
|
||||
MDict["avg"] = temp
|
||||
except Exception as e:
|
||||
print(f"[WARN] Could not parse AVG line: {line} ({e})", flush=True)
|
||||
continue
|
||||
# continue
|
||||
|
||||
|
||||
# {'bp1': 35, 'bp2': 29, 'sim0': 35, 'sim1': 33, 'exp0': 56, 'exp1': 54, 'avg': 40}
|
||||
# process_temps(MDict)
|
||||
fluxSending = True
|
||||
|
||||
return MDict
|
||||
|
||||
|
||||
def setSpeed(inSpeeDict: dict):
|
||||
|
||||
bpavrg = 0
|
||||
# default
|
||||
outfanprcntg = 0
|
||||
|
||||
# get backplanbe average
|
||||
if "bp1" in inSpeeDict and "bp2" in inSpeeDict:
|
||||
bpavrg = (inSpeeDict["bp1"] + inSpeeDict["bp2"]) /2
|
||||
outfanprcntg = int((bpavrg / (HIGH_FAN_TRSHD - LOW_FAN_TRSHD)) * TEMP_FACTOR)
|
||||
# os.system(f"echo setting {outfanprcntg}%")
|
||||
|
||||
# Set fan speed
|
||||
if outfanprcntg >= 20:
|
||||
MDserial.write((f"{SETFANCMND} {str(outfanprcntg)} \n\r").encode())
|
||||
print(f"setting {outfanprcntg}%", flush=True)
|
||||
return 0
|
||||
else:
|
||||
# Set default value
|
||||
MDserial.write((f"{SETFANCMND} {str(DEFOUTPRCNTG)} \n\r").encode())
|
||||
return 1
|
||||
|
||||
# If something goes super wrong
|
||||
return -1
|
||||
|
||||
|
||||
|
||||
# Check if UART is used
|
||||
# Not neede because when defining MDserial it gets automatically opened
|
||||
# Will leave it here anyway
|
||||
# try:
|
||||
# MDserial.open()
|
||||
# except serial.serialutil.SerialException:
|
||||
# # MDserial.close()
|
||||
# # MDserial.open()
|
||||
# print("Port allready opened.\nTry closing it first")
|
||||
|
||||
# Threaded flow processor
|
||||
def process_temps():
|
||||
global MDict, fluxSending
|
||||
|
||||
while True:
|
||||
# ---LeData---
|
||||
# {'bp1': 35, 'bp2': 29, 'sim0': 35, 'sim1': 34, 'exp0': 56, 'exp1': 54}
|
||||
# ---LeData---
|
||||
if fluxSending:
|
||||
# Prep InfluxDB data
|
||||
# ---------------------UNCOMMENT-----------------------
|
||||
# inflxdb_Data_To_Send = (
|
||||
# influxdb_client.Point(f"{measurement}-script")
|
||||
# .tag("MACHINE", MACHINE_TAG)
|
||||
# .tag("LOCATION", LOCATION)
|
||||
# .field("Backplane1", MDict["bp1"])
|
||||
# .field("Backplane2", MDict["bp2"])
|
||||
# .field("SASIntModule0", MDict["sim0"])
|
||||
# .field("SASIntModule1", MDict["sim1"])
|
||||
# .field("Expander0", MDict["exp0"])
|
||||
# .field("Expander1", MDict["exp1"])
|
||||
# .field("Average", MDict["avg"])
|
||||
# )
|
||||
|
||||
# inflxdb_Datazz_To_Send.append(inflxdb_Data_To_Send)
|
||||
# # Send data to InfluxDB
|
||||
# write_api.write(bucket=bucket, org=org, record=inflxdb_Data_To_Send)
|
||||
# # time.sleep(INFLX_SEPARATE_POINTS) # separate points
|
||||
|
||||
# # print(f"{len(bigDict)} <--- This many entrys")
|
||||
|
||||
|
||||
# # Clean up before another loop
|
||||
# bigDict.clear()
|
||||
# inflxdb_Datazz_To_Send.clear()
|
||||
# ---------------------UNCOMMENT-----------------------
|
||||
print("I'm sending stuff to InfluxDB")
|
||||
|
||||
fluxSending = False
|
||||
|
||||
|
||||
# print("----------------")
|
||||
# return ()
|
||||
else:
|
||||
continue
|
||||
|
||||
|
||||
|
||||
|
||||
# Init
|
||||
MDict = getTemp()
|
||||
lastTempReading = time.time()
|
||||
|
||||
def mainCodeHere():
|
||||
while True:
|
||||
global MDict, fluxSending, currentTime, lastTempReading
|
||||
# https://stackoverflow.com/questions/52578122/not-able-to-send-the-enter-command-on-pyserial
|
||||
|
||||
# get temperature data, wait for MD1200 to answer and store
|
||||
|
||||
currentTime = time.time()
|
||||
|
||||
if currentTime - lastTempReading >= TEMPREADINTERVAL:
|
||||
getTemp()
|
||||
lastTempReading = currentTime
|
||||
|
||||
if MDict:
|
||||
setSpeedrcode = setSpeed(MDict)
|
||||
|
||||
# good
|
||||
if setSpeedrcode == 0:
|
||||
pass
|
||||
# print("Were mint", flush=True)
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# not good
|
||||
elif setSpeedrcode == 1:
|
||||
print("Ambigous temperature readings.\nFalling back to safe values.", flush=True)
|
||||
# time.sleep(EPPYSLEEPY)
|
||||
# very not good
|
||||
elif setSpeedrcode == -1:
|
||||
print("o nyo", flush=True)
|
||||
exit()
|
||||
# very very very not good
|
||||
else:
|
||||
print("idk", flush=True)
|
||||
exit()
|
||||
else:
|
||||
print(f"temperature not yet pulled.\nFalling back do default fan speed", flush=True)
|
||||
# os.system(f"echo temperature not yet pulled.\nFalling back do default fan speed")
|
||||
MDserial.write((f"{SETFANCMND} {str(DEFOUTPRCNTG)} \n\r").encode())
|
||||
|
||||
time.sleep(EPPYSLEEPY)
|
||||
|
||||
|
||||
# Prepare threads and launch them
|
||||
thread_main = threading.Thread(target=mainCodeHere)
|
||||
thread_flux = threading.Thread(target=process_temps)
|
||||
|
||||
thread_main.start()
|
||||
thread_flux.start()
|
||||
|
||||
thread_main.join()
|
||||
thread_flux.join()
|
14
PC_CONTROL_CODE/dockerInflux/md1200.env
Normal file
14
PC_CONTROL_CODE/dockerInflux/md1200.env
Normal file
@ -0,0 +1,14 @@
|
||||
# baud_rate=
|
||||
# serial_adapter=
|
||||
# wait_time=
|
||||
# temp_factor=
|
||||
# lower_treshold=
|
||||
# upper_treshold=
|
||||
INFLUX_TOKEN=apg1gysUeCcxdcRTMmosJTenbEppmUNi9rXlANDB2oNadBdWAu2GVTDc_q_dyo0iyYsckKaOvPRm6ba2NK0y_A==
|
||||
INFLUX_BUCKET=JBOD
|
||||
INFLUX_ORG=staging
|
||||
INFLUX_URL=http://localhost:8086
|
||||
INFLUX_MEASUREMENT=MD1200
|
||||
INFLUX_MACHINE_TAG=CHONGUS1200
|
||||
INFLUX_LOCATION=HQ
|
||||
INFLX_SEPARATE_POINTS=0.1
|
18
docker-compose.yml
Normal file
18
docker-compose.yml
Normal file
@ -0,0 +1,18 @@
|
||||
---
|
||||
|
||||
services:
|
||||
mdfanchanger:
|
||||
container_name: MD_Fan_Changer
|
||||
image: yuruc3/md1200_fan_controll:v1.2.1
|
||||
environment:
|
||||
# - MD1200BAUD=
|
||||
- SERIALADAPTER=/dev/ttyUSB0
|
||||
- TEMP_FACTOR=17
|
||||
- EPPYSLEEPY=0.25
|
||||
- MDSERIALTIMEOUT=0.75
|
||||
# - LOW_FAN_TRSHD=
|
||||
# - HIGH_FAN_TRSHD=
|
||||
devices:
|
||||
- /dev/ttyUSB0:/dev/ttyUSB0
|
||||
restart: unless-stopped
|
||||
privileged: false
|
Loading…