Added OIDs for IDRAC9 as they are slightly different from 7 and 8

This commit is contained in:
2026-03-01 21:28:58 +01:00
parent 11dc0397e7
commit 583a72ac98

52
MIBs.md
View File

@@ -1,4 +1,4 @@
# IDRAC8
# IDRAC7/8
## temperatureProbeReading
@@ -67,6 +67,56 @@ Uptime in seconds
# IDRAC9
Here the power OID is different :(
## Power
Here are the OIDs for string
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.8.1.1 = STRING: "PS1 Current 1"
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.8.1.2 = STRING: "PS2 Current 2"
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.8.1.3 = STRING: "System Board Pwr Consumption"
### Current and Watts
and here are OIDs for intigers. They show miliamps*100. So when ...6.1.1 show 2 it means 2/10 so 100mA = 0.1A.
BUT the last one is the total board power which is in Watts
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.6.1.1 = INTEGER: 2
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.6.1.2 = INTEGER: 10
SNMPv2-SMI::enterprises.674.10892.5.4.600.30.1.6.1.3 = INTEGER: 240
### Voltage
Here are OIDs for Voltage. They need to be divided by 1000 to get 236.000 Volts
PSU1 and PSU2
SNMPv2-SMI::enterprises.674.10892.5.4.600.20.1.6.1.33 = INTEGER: 236000
SNMPv2-SMI::enterprises.674.10892.5.4.600.20.1.6.1.34 = INTEGER: 236000
## Temperatures
Here are the strings for the temp readings
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.8.1.1 = STRING: "CPU1 Temp"
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.8.1.2 = STRING: "CPU2 Temp"
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.8.1.3 = STRING: "System Board Inlet Temp"
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.8.1.4 = STRING: "System Board Exhaust Temp"
These are temperature readings for inlet and exhaust. They need to be divided by 10 so that 260/10 = 26 C
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.6.1.1 = INTEGER: 550
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.6.1.2 = INTEGER: 560
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.6.1.3 = INTEGER: 260
SNMPv2-SMI::enterprises.674.10892.5.4.700.20.1.6.1.4 = INTEGER: 310
# NXOS 9.3